CC1000
SWRS048A Page 14 of 55
Figure 5. Configuration registers read operation
Parameter Symbol
Min Max Units Conditions
PCLK, clock
frequency
F
CLOCK
- 10 MHz
PCLK low
pulse
duration
T
CL,min
50 ns The minimum time PCLK must be low.
PCLK high
pulse
duration
T
CH,min
50 ns The minimum time PCLK must be high.
PALE setup
time
T
SA
10 - ns The minimum time PALE must be low before
negative edge of PCLK.
PALE hold
time
T
HA
10 - ns The minimum time PALE must be held low after
the positive edge of PCLK.
PDATA setup
time
T
SD
10 - ns The minimum time data on PDATA must be ready
before the negative edge of PCLK.
PDATA hold
time
T
HD
10 - ns The minimum time data must be held at PDATA,
after the negative edge of PCLK.
Rise time T
rise
100 ns The maximum rise time for PCLK and PALE
Fall time T
fall
100 ns The maximum fall time for PCLK and PALE
Note: The set-up- and hold-times refer to 50% of VDD.
Table 2. Serial interface, timing specification
PCLK
Address Read mode
6543210
R 7 6 5 4 3 2 1 0
Data byte
PALE
PDATA